ANALISA HUBUNG SINGKAT PADA PLTMG AMBON PEAKER 30 MW
DOI:
https://doi.org/10.54463/q5war159Abstract
With the increasing demand for electricity in Indonesia, both industrial and household, a reliable electrical system is required. One of the electrical system faults, such as a short-circuit fault in a generator, can disrupt electricity delivery and cause damage to equipment. This research concentrates on analyzing short circuit faults in the Ambon Peaker Gas Oil Power Plant (PLTMG), which has four generator units with a capacity of 30 MW. The main objective of this study is to determine how much short-circuit fault current occurs during three-phase, phase-phase, and phase-ground faults, as well as the components that affect these currents. Data collection on power system characteristics and the use of ETAP (Electrical Transient Analysis Program) software were used. The results showed that there was a short-circuit current fault at bus 1 of the Ambon MHP with a three-phase fault of 14.727 kA, a ground-phase fault of 15.998 kA, and a phase-phase fault of 12.926 kA. With these results, this study provides recommendations for the selection of appropriate protection equipment to minimize losses due to disturbances in the power system at the Ambon Peaker MHP.
Keyword : Short circuit fault, PLTMG, ETAP
References
[1] Sari, P. (2017). Gangguan Hubung Singkat. Pembangkitan Energi Listrik, 7(1), 4–31.
[2] Gordon. (2019). ?BAB 2 Tinjauan Pustaka. Pontificia Universidad Catolica Del Peru, 8(33), 44.
[3] Agusthinus S. Sampeallo, Nursalim, P. J. F. (2015). Analisis Gangguan Hubung Singkat pada
Jaringan Pemakaian Sendiri PLTU Bolok PT. SMSE (IPP) Unit 3 dan 4 Menggunakan SOFTWARE
ETAP 12.6.0
[4] Aryamantara, K. J., Giriantari, I. A. ., & Sukerayasa, I. . (2018). Analisis Hubung Singkat Pada
Jaringan Tegangan Menengah 20 kV Penyulang Kedonganan. Majalah Ilmiah Teknologi Elektro,
17(2), 213.
[5] Gaffar, A., Agussalim, A., & Arisandi, D. (2017). Analisis Gangguan Hubung Singkat pada jaringan
Distribusi 20 Kv Di Gardu Induk Panakkukang. Jurnal Teknologi Elekterika, 14(2), 156.
[6] Samin, T. (2019). Analisa Gangguan Hubung Singkat Satu Fasa ke Tanah pada Jaringan Distribusi
20 KV PT. PLN (PERSERO) Sebatik menggunakan Software ETAP Power Station 12.6.0. Elektrika
Borneo, 5(1), 19–24.
[7] Pahiyanti, N. G. (2024). Gangguan Hubung Singkat Gas SO2 Terhadap Gas SF6 PMT 150 kV di GI
Durikosambi. Sutet, 13(2), 91–100.
Downloads
Published
Issue
Section
License

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.









